FastQCFastQC Report
Sun 4 Sep 2022
EGAF00001852005

Summary

[OK]Basic Statistics

MeasureValue
FilenameEGAF00001852005
File typeConventional base calls
EncodingSanger / Illumina 1.9
Total Sequences739896
Sequences flagged as poor quality0
Sequence length151
%GC49

[OK]Per base sequence quality

Per base quality graph

[OK]Per tile sequence quality

Per tile quality graph

[OK]Per sequence quality scores

Per Sequence quality graph

[WARN]Per base sequence content

Per base sequence content

[WARN]Per sequence GC content

Per sequence GC content graph

[OK]Per base N content

N content graph

[OK]Sequence Length Distribution

Sequence length distribution

[FAIL]Sequence Duplication Levels

Duplication level graph

[WARN]Overrepresented sequences

SequenceCountPercentagePossible Source
GTATCAACGCAGAGTACTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTT33030.4464140906289532No Hit
TATCAACGCAGAGTACTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTT22810.30828657000443305No Hit
ATATTAAAGTTGCTGCAGTTAAAAAGCTCGTAGTTGGATCTTGGGAGCGG17750.2398985803410209No Hit
GGTATCAACGCAGAGTACTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTT14220.1921891725323559No Hit
GATTAAGAGGGACGGCCGGGGGCATTCGTATTGCGCCGCTAGAGGTGAAA12740.17218636132645668No Hit
GTACTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTT11610.15691394466249312No Hit
CCATTATTCCTAGCTGCGGTATCCAGGCGGCTCGGGCCTGCTTTGAACAC10910.14745315557862185No Hit
CTCTTAATCATGGCCTCAGTTCCGAAAACCAACAAAATAGAACCGCGGTC10870.14691253905954352No Hit
GAATAACGCCGCCGCATCGCCGGTCGGCATCGTTTATGGTCGGAACTACG10360.14001967844129445No Hit
CTTTAATATACGCTATTGGAGCTGGAATTACCGCGGCTGCTGGCACCAGA9920.13407289673143252No Hit
TCGTAGTTCCGACCATAAACGATGCCGACCGGCGATGCGGCGGCGTTATT9770.1320455847848887No Hit
GTACATGGGTACCTGGTTGATCCTGCCAGTAGCATATGCTTGTCTCAAAG9700.13109950587650154No Hit
GTACATGGGGAATAATTGCAATCCCCGATCCCCATCACGAATGGGGTTCA9110.12312541222009579No Hit
TATCTAGAGTCACCAAAGCCGCCGGCGCCCGCCCCCCGGCCGGGGCCGGA8990.12150356266286072No Hit
GCTAAGAGCATCGAGGGGGCGCCGAGAGGCAAGGGGCGGGGACGGGCGGT8630.1166380139911555No Hit
GTACATGGGAAGCAGTGGTATCAACGCAGAGTACATGGGAAGCAGTGGTA8550.11555678095299882Clontech SMARTer II A Oligonucleotide (100% over 25bp)
GAATAGGACCGCGGTTCTATTTTGTTGGTTTTCGGAACTGAGGCCATGAT8480.11461070204461167No Hit
GTATCTGATCGTCTTCGAACCTCCGACTTTCGTTCTTGATTAATGAAAAC8480.11461070204461167No Hit
CTATTGGAGCTGGAATTACCGCGGCTGCTGGCACCAGACTTGCCCTCCAA8390.11339431487668537No Hit
GCTTTGAACACTCTAATTTTTTCAAAGTAAACGCTTCGGGCCCCGCGGGA8050.10879907446451935No Hit
CTCTAATTTTTTCAAAGTAAACGCTTCGGGCCCCGCGGGACACTCAGCTA8000.1081233038156714No Hit
ATTCCTAGCTGCGGTATCCAGGCGGCTCGGGCCTGCTTTGAACACTCTAA7980.1078529955561322No Hit
ACGCAGAGTACTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTT7920.10704207077751468No Hit
AGATAACCTCGGGCCGATCGCACGCCCCCCGTGGCGGCGACGACCCATTC7910.1069069166477451No Hit
TATTAAAGTTGCTGCAGTTAAAAAGCTCGTAGTTGGATCTTGGGAGCGGG7870.10636630012866673No Hit
ATCAGATACCGTCGTAGTTCCGACCATAAACGATGCCGACCGGCGATGCG7800.10542022122027961No Hit
GTTAAAAAGCTCGTAGTTGGATCTTGGGAGCGGGCGGGCGGTCCGCCGCG7630.1031226010141966No Hit
GAATAATGGAATAGGACCGCGGTTCTATTTTGTTGGTTTTCGGAACTGAG7610.1028522927546574No Hit

[WARN]Adapter Content

Adapter graph