FastQCFastQC Report
Tue 10 May 2022
EGAF00003633103

Summary

[OK]Basic Statistics

MeasureValue
FilenameEGAF00003633103
File typeConventional base calls
EncodingSanger / Illumina 1.9
Total Sequences490769
Sequences flagged as poor quality0
Sequence length100
%GC45

[OK]Per base sequence quality

Per base quality graph

[WARN]Per tile sequence quality

Per tile quality graph

[OK]Per sequence quality scores

Per Sequence quality graph

[FAIL]Per base sequence content

Per base sequence content

[FAIL]Per sequence GC content

Per sequence GC content graph

[OK]Per base N content

N content graph

[OK]Sequence Length Distribution

Sequence length distribution

[FAIL]Sequence Duplication Levels

Duplication level graph

[FAIL]Overrepresented sequences

SequenceCountPercentagePossible Source
GTACATGGGAAGCAGTGGTATCAACGCAGAGTACATGGGAAGCAGTGGTA65791.3405492196939905Clontech SMARTer II A Oligonucleotide (100% over 25bp)
CCCATGTACTCTGCGTTGATACCACTGCTTCCCATGTACTCTGCGTTGAT33050.6734329185421247Clontech Universal Primer Mix Long (96% over 26bp)
GTATCAACGCAGAGTACATGGGAAGCAGTGGTATCAACGCAGAGTACATG31710.6461288304681021Clontech SMARTer II A Oligonucleotide (100% over 25bp)
GAGTACATGGGAAGCAGTGGTATCAACGCAGAGTACATGGGAAGCAGTGG23380.47639520833630483Clontech Universal Primer Mix Long (96% over 26bp)
CTTATACACATCTCCGAGCCCACGAGACTCGTTCGTCGGGATCTCGTATG21790.44399707397981536No Hit
TATCAACGCAGAGTACATGGGAAGCAGTGGTATCAACGCAGAGTACATGG21500.43808798029215373Clontech Universal Primer Mix Long (96% over 26bp)
GTATCAACGCAGAGTACTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTT20830.4244359362551424No Hit
GGTATCAACGCAGAGTACATGGGAAGCAGTGGTATCAACGCAGAGTACAT15150.3086992047174944Clontech SMARTer II A Oligonucleotide (100% over 25bp)
GTACATGGGGCAGTGGTATCAACGCAAAAAAAAAAAAAAAAAAAAAAAAA15030.3062540625019103No Hit
ATACACATCTCCGAGCCCACGAGACTCGTTCGTCGGGATCTCGTATGCCG14660.29871487400385927No Hit
CTTATACACATCTCCGAGCCCACGAGACTCGTTCGTCGGGATCGCGTATG13890.28302521145386117No Hit
GGTATCAACGCAGAGTACTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTT13310.271207024078538No Hit
GCTTCCCATGTACTCTGCGTTGATACCACTGCTTCCCATGTACTCTGCGT12650.2577587418928253Clontech Universal Primer Mix Long (96% over 26bp)
ACGCAGAGTACATGGGAAGCAGTGGTATCAACGCAGAGTACATGGGAAGC12490.2544985522720465Clontech Universal Primer Mix Long (96% over 26bp)
GTATCAACGCAGAGTACATGGGAAGCAGTGGTATCAACGCAGAGTACTTT11060.22536060753633583Clontech SMART CDS Primer II A (100% over 26bp)
GCGTTGATACCACTGCTTCCCATGTACTCTGCGTTGATACCACTGCTTCC9210.18766466504608073Clontech SMART CDS Primer II A (96% over 26bp)
ATACACATCTCCGAGCCCACGAGACTCGTTCGTCGGGATCGCGTATGCCG9170.18684961764088603No Hit
GTACATGGGAAGCAGTGGTATCAACGCAGAGTACTTTTTTTTTTTTTTTT8840.1801254765480297Clontech SMART CDS Primer II A (100% over 26bp)
CATGTACTCTGCGTTGATACCACTGCTTCCCATGTACTCTGCGTTGATAC8150.16606590880842106Clontech Universal Primer Mix Long (96% over 26bp)
TATCAACGCAGAGTACTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTT7960.16219443363374622No Hit
ACACATCTCCGAGCCCACGAGACTCGTTCGTCGGGATCTCGTATGCCGTC7950.16199067178244753No Hit
CAGTGGTATCAACGCAGAGTACATGGGAAGCAGTGGTATCAACGCAGAGT6860.13978062999089183Clontech Universal Primer Mix Long (100% over 23bp)
GTATCAACGCAGAGTACATGGGGCAGTGGTATCAACGCAAAAAAAAAAAA6670.135909154816217No Hit
TATCAACGCAGAGTACATGGGAAGCAGTGGTATCAACGCAGAGTACTTTT6440.13122263223634745Clontech Universal Primer Mix Long (96% over 26bp)
CATGGGAAGCAGTGGTATCAACGCAGAGTACATGGGAAGCAGTGGTATCA6250.1273511570616726Clontech Universal Primer Mix Long (96% over 26bp)
ACACATCTCCGAGCCCACGAGACTCGTTCGTCGGGATCGCGTATGCCGTC6110.12449849114349112No Hit
GGGAAGCAGTGGTATCAACGCAGAGTACATGGGAAGCAGTGGTATCAACG5700.11614425524024541Clontech Universal Primer Mix Long (96% over 26bp)
GTACATGGGCAGTGGTATCAACGCAAAAAAAAAAAAAAAAAAAAAAAAAA5680.11573673153764806No Hit
GTGGTATCAACGCAGAGTACATGGGAAGCAGTGGTATCAACGCAGAGTAC5380.10962387599868777Clontech SMARTer II A Oligonucleotide (100% over 25bp)
AAGCAGTGGTATCAACGCAGAGTACATGGGAAGCAGTGGTATCAACGCAG5110.10412230601362352Clontech SMARTer II A Oligonucleotide (100% over 25bp)

[OK]Adapter Content

Adapter graph