FastQCFastQC Report
Tue 28 Jun 2022
EGAF00004962941

Summary

[OK]Basic Statistics

MeasureValue
FilenameEGAF00004962941
File typeConventional base calls
EncodingSanger / Illumina 1.9
Total Sequences119810181
Sequences flagged as poor quality0
Sequence length91
%GC43

[OK]Per base sequence quality

Per base quality graph

[OK]Per tile sequence quality

Per tile quality graph

[OK]Per sequence quality scores

Per Sequence quality graph

[FAIL]Per base sequence content

Per base sequence content

[FAIL]Per sequence GC content

Per sequence GC content graph

[OK]Per base N content

N content graph

[OK]Sequence Length Distribution

Sequence length distribution

[FAIL]Sequence Duplication Levels

Duplication level graph

[FAIL]Overrepresented sequences

SequenceCountPercentagePossible Source
AAGCAGTGGTATCAACGCAGAGTACATGGGGAAAAAAAAAAAAAAAAAAA18038581.5055965903264932Clontech SMARTer II A Oligonucleotide (100% over 25bp)
AAGCAGTGGTATCAACGCAGAGTACATGGGGGAAAAAAAAAAAAAAAAAA15579851.3003778034522793Clontech SMARTer II A Oligonucleotide (100% over 25bp)
AAGCAGTGGTATCAACGCAGAGTACATGGGATAAACTTCGCCTTAATTTT6054240.5053193267440269Clontech SMARTer II A Oligonucleotide (100% over 25bp)
AAGCAGTGGTATCAACGCAGAGTACATGGGAAAAAAAAAAAAAAAAAAAA5788970.48317847045068735Clontech SMARTer II A Oligonucleotide (100% over 25bp)
AAGCAGTGGTATCAACGCAGAGTACATGGGAGAAAAAAAAAAAAAAAAAA4018130.3353746707051548Clontech SMARTer II A Oligonucleotide (100% over 25bp)
AAGCAGTGGTATCAACGCAGAGTACATGGGGAGAAAAAAAAAAAAAAAAA3231970.26975754255809026Clontech SMARTer II A Oligonucleotide (100% over 25bp)
AAGCAGTGGTATCAACGCAGAGTACATGGGGGGAAAAAAAAAAAAAAAAA2529240.21110392947323897Clontech SMARTer II A Oligonucleotide (100% over 25bp)
AAGCAGTGGTATCAACGCAGAGTACATGGGGCTAAACCTAGCCCCAAACC1958140.16343686184732498Clontech SMARTer II A Oligonucleotide (100% over 25bp)
GCAGTGGTATCAACGCAGAGTACATGGGGAAAAAAAAAAAAAAAAAAAAA1850380.1544426345537363Clontech SMARTer II A Oligonucleotide (100% over 23bp)
GGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGG1789100.14932787723607563No Hit
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA1706900.14246702456780364No Hit
GCAGTGGTATCAACGCAGAGTACATGGGGGAAAAAAAAAAAAAAAAAAAA1622920.13545760355708Clontech SMARTer II A Oligonucleotide (100% over 23bp)
CAGTGGTATCAACGCAGAGTACATGGGGAAAAAAAAAAAAAAAAAAAAAA1535470.12815855774393664Clontech SMARTer II A Oligonucleotide (100% over 22bp)
CAGTGGTATCAACGCAGAGTACATGGGGGAAAAAAAAAAAAAAAAAAAAA1413630.11798913816848336Clontech SMARTer II A Oligonucleotide (100% over 22bp)
GTGGTATCAACGCAGAGTACATGGGGAAAAAAAAAAAAAAAAAAAAAAAA1249390.10428078728968784No Hit
AAGCAGTGGTATCAACGCAGAGTACATGGGGAGAGAAAAAAAAAAAAAAA1241030.10358301687233074Clontech SMARTer II A Oligonucleotide (100% over 25bp)
GCAGTGGTATCAACGCAGAGTACATGGGATAAACTTCGCCTTAATTTTAA1218440.10169753436896987Clontech SMARTer II A Oligonucleotide (100% over 23bp)

[OK]Adapter Content

Adapter graph