FastQCFastQC Report
Sat 2 Jul 2022
EGAF00005413207

Summary

[OK]Basic Statistics

MeasureValue
FilenameEGAF00005413207
File typeConventional base calls
EncodingSanger / Illumina 1.9
Total Sequences162049107
Sequences flagged as poor quality0
Sequence length91
%GC44

[OK]Per base sequence quality

Per base quality graph

[OK]Per tile sequence quality

Per tile quality graph

[OK]Per sequence quality scores

Per Sequence quality graph

[FAIL]Per base sequence content

Per base sequence content

[FAIL]Per sequence GC content

Per sequence GC content graph

[OK]Per base N content

N content graph

[OK]Sequence Length Distribution

Sequence length distribution

[FAIL]Sequence Duplication Levels

Duplication level graph

[WARN]Overrepresented sequences

SequenceCountPercentagePossible Source
AAGCAGTGGTATCAACGCAGAGTACATGGGGAAAAAAAAAAAAAAAAAAA7868260.4855478777800361Clontech SMARTer II A Oligonucleotide (100% over 25bp)
AAGCAGTGGTATCAACGCAGAGTACATGGGGGAAAAAAAAAAAAAAAAAA6596980.4070975843143646Clontech SMARTer II A Oligonucleotide (100% over 25bp)
AAGCAGTGGTATCAACGCAGAGTACATGGGAAAAAAAAAAAAAAAAAAAA5659560.3492496876270969Clontech SMARTer II A Oligonucleotide (100% over 25bp)
AAGCAGTGGTATCAACGCAGAGTACATGGGGCTAAACCTAGCCCCAAACC5448970.3362542442149959Clontech SMARTer II A Oligonucleotide (100% over 25bp)
AAGCAGTGGTATCAACGCAGAGTACATGGGAGAAAAAAAAAAAAAAAAAA3796160.2342598530950251Clontech SMARTer II A Oligonucleotide (100% over 25bp)
AAAAAATTTAACACCCATAGTAGGCCTAAAAGCAGCCACCAATTAAGAAA3591670.221640838785986No Hit
AAGCAGTGGTATCAACGCAGAGTACATGGGATAGGTTTGGTCCTAGCCTT3276290.20217883706079293Clontech SMARTer II A Oligonucleotide (100% over 25bp)
AAGCAGTGGTATCAACGCAGAGTACATGGGATAAACTTCGCCTTAATTTT2789940.17216632980273072Clontech SMARTer II A Oligonucleotide (100% over 25bp)
CAAACATATAACTGAACTCCTCACACCCAATTGGACCAATCTATCACCCT2777620.17140606643392364No Hit
CTAAAAAATCCCAAACATATAACTGAACTCCTCACACCCAATTGGACCAA2628920.16222983567567578No Hit
GACCAATCTATCACCCTATAGAAGAACTAATGTTAGTATAAGTAACATGA2491060.1537225379464757No Hit
AAAAAATCCCAAACATATAACTGAACTCCTCACACCCAATTGGACCAATC2381030.14693262086288447No Hit
CTGAACTCCTCACACCCAATTGGACCAATCTATCACCCTATAGAAGAACT2208730.13630004144361005No Hit
CCAATCTATCACCCTATAGAAGAACTAATGTTAGTATAAGTAACATGAAA2174680.13419882653225604No Hit
AATTGGACCAATCTATCACCCTATAGAAGAACTAATGTTAGTATAAGTAA2103550.1298094163517976No Hit
GTTCAAGCTCAACACCCACTACCTAAAAAATCCCAAACATATAACTGAAC2080710.1283999670544312No Hit
CCCAATTGGACCAATCTATCACCCTATAGAAGAACTAATGTTAGTATAAG2045740.1262419792291728No Hit
CACCAATTAAGAAAGCGTTCAAGCTCAACACCCACTACCTAAAAAATCCC2039820.12587665787013563No Hit
GCTCAACACCCACTACCTAAAAAATCCCAAACATATAACTGAACTCCTCA1917490.11832771161151787No Hit
CTCACACCCAATTGGACCAATCTATCACCCTATAGAAGAACTAATGTTAG1876220.11578095274539218No Hit
GGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGG1807060.11151311065231602No Hit
AATCTATCACCCTATAGAAGAACTAATGTTAGTATAAGTAACATGAAAAC1737040.10719219822667705No Hit
AAAAATTTAACACCCATAGTAGGCCTAAAAGCAGCCACCAATTAAGAAAG1736070.1071323398283213No Hit
AAGCAGTGGTATCAACGCAGAGTACATGGGAAAAGTTGCTGCAGTTAAAA1668330.10295212549366285Clontech SMARTer II A Oligonucleotide (100% over 25bp)
CTCCTCACACCCAATTGGACCAATCTATCACCCTATAGAAGAACTAATGT1650130.10182900915337967No Hit
AAAATCCCAAACATATAACTGAACTCCTCACACCCAATTGGACCAATCTA1638740.10112613579536726No Hit

[OK]Adapter Content

Adapter graph